############################################################ ATACT Started -- Tue Jan 01 01:19:15 1980 ATACT -- ATA Command Test -- Version 5A0b -- using ATADRVR Version 17A. Copyright 1997-2014 by Hale Landis. All rights reserved. Technical Support: http://www.ata-atapi.com/techsupp.html This copy purchased by: FULL FREE VERSION (2019,FullFreeVersion). Customer id and number: c_free 9998. No ATAERROR environment variable found. Command line: A:\ATACT.EXE po Invalid option: 'po' ! One or more invalid command line options found ! For help, execute the program again with no command line options. ATACT Ended -- Tue Jan 01 01:19:16 1980 ############################################################ ############################################################ ATACT Started -- Tue Jan 01 01:19:34 1980 ATACT -- ATA Command Test -- Version 5A0b -- using ATADRVR Version 17A. Copyright 1997-2014 by Hale Landis. All rights reserved. Technical Support: http://www.ata-atapi.com/techsupp.html This copy purchased by: FULL FREE VERSION (2019,FullFreeVersion). Customer id and number: c_free 9998. No ATAERROR environment variable found. Command line: A:\ATACT.EXE /? Invalid option: '/?' ! One or more invalid command line options found ! For help, execute the program again with no command line options. ATACT Ended -- Tue Jan 01 01:19:35 1980 ############################################################ ############################################################ ATACT Started -- Tue Jan 01 01:19:52 1980 ATACT -- ATA Command Test -- Version 5A0b -- using ATADRVR Version 17A. Copyright 1997-2014 by Hale Landis. All rights reserved. Technical Support: http://www.ata-atapi.com/techsupp.html This copy purchased by: FULL FREE VERSION (2019,FullFreeVersion). Customer id and number: c_free 9998. No ATAERROR environment variable found. Command line: A:\ATACT.EXE Po Invalid option: 'Po' ! One or more invalid command line options found ! For help, execute the program again with no command line options. ATACT Ended -- Tue Jan 01 01:19:53 1980 ############################################################ ############################################################ ATACT Started -- Tue Jan 01 01:20:11 1980 ATACT -- ATA Command Test -- Version 5A0b -- using ATADRVR Version 17A. Copyright 1997-2014 by Hale Landis. All rights reserved. Technical Support: http://www.ata-atapi.com/techsupp.html This copy purchased by: FULL FREE VERSION (2019,FullFreeVersion). Customer id and number: c_free 9998. No ATAERROR environment variable found. Command line: A:\ATACT.EXE c: Invalid option: 'c:' ! One or more invalid command line options found ! For help, execute the program again with no command line options. ATACT Ended -- Tue Jan 01 01:20:12 1980 ############################################################ ############################################################ ATACT Started -- Tue Jan 01 01:20:30 1980 ATACT -- ATA Command Test -- Version 5A0b -- using ATADRVR Version 17A. Copyright 1997-2014 by Hale Landis. All rights reserved. Technical Support: http://www.ata-atapi.com/techsupp.html This copy purchased by: FULL FREE VERSION (2019,FullFreeVersion). Customer id and number: c_free 9998. No ATAERROR environment variable found. Command line: A:\ATACT.EXE Help for ATACT: ATACT io-mode-option [general-options] One of these io-mode-option is required: PROMPT - Prompt for PCI controller to use. b:d:f:x - b:d:f is the PCI bus, device and function for an ATA controller, x is the device on that controller, P0, P1, P01, S0, S1 or S01. P0 or P1 or P01 - Use traditional/legacy primary devies 0, 1 or both. S0 or S1 or S01 - Use traditional/legacy secondary device 0, 1 or both. PCCMODE=mode - Use PC Card mode, see doc file PCC.HTM. Examples: ATACT 1:1:0:S0 SEQ=WRN NOPM IGNORE=DC ATACT 0:31:1:P01 READONLY STOP ATACT S1 SEQ=N IDP=NONE NOCACHE ATACT PCCMODE=MEMORY SEQ=N IDP=NONE NOCACHE These general-options are optional: CACHE - Use Set Features to turn R/W caching on/off. CFA - Use the CFA commands. CHT=ALL - Full command history trace (default). CHT=NONE - No command history trace. CHT=x - Command history trace, see doc file ATACT.HTM. COMPARE=FULL - Full data compare (default). COMPARE=NONE - No data compare. COMPARE=QUICK - Quick data compare. DEBUG=n - Enable debug messages up to level n. DMA - Use Read/Write DMA commands. DUMPCHT=n1:n2 - Dump CHT at or after commands n1 or n2. FUA - Use R/W DMA/Multiple FUA commands. IDP=ALL - Init Device Param uses all values. IDP=DEFAULT - Init Device Param uses drive's default. IDP=NONE - No CHS testing. IDP=NORMAL - Init Device Param uses up to 16 and 63 (default). These general-options are optional: IGNORE=ALL - Ignore all DC, RE and WE errors. IGNORE=DC - Ignore Data Compare errors. IGNORE=RE - Ignore Read Errors. IGNORE=WE - Ignore Write Errors. INTerrupt - Run in interrupt mode. IRQ=n - IRQ to use (not shared). IRQ=Sn - IRQ to use (shared). LLT - Low level trace on all device errors. LOG=fileName - Log file name. MAXSIZE=nK - Restrict size of the drive. MAXSIZE=nM - Restrict size of the drive. MAXTL=n - Restrict transfer legnth (sector counts). MINLBA=nK - Restrict size of the drive. MINLBA=nM - Restrict size of the drive. NOCACHE - Do not use Set Features to turn R/W caching on/off. NOCFA - Do not use the CFA commands. NODMA - Do not use Read/Write DMA commads. NOFUA - Do not use R/W DMA/Multiple FUA commands. NOLLT - No low level trace of all device errors (default). These general-options are optional: NONSTD=x - Non standard operations, see below. NOPM - No power management commands. NOSTOP - No stop on first error (default). OKTOWRITE - OK to write over user data. PIO=BYTE - Set 8-bit PIO mode, see doc file PIO.HTM. PIO=DWORD - Set 32-bit PIO mode, see doc file PIO.HTM. PIO=WORD - Set 16-bit PIO mode, see doc file PIO.HTM. PIO=NONE - Use mostly read/write DMA commands. PIO=ODR0 - Use Data register at offset 0H. PIO=ODR8 - Use Data register at offset 8H. PIO=ODR400 - Use Data register at offset 400H. PIO=ODRRAND - Pick Data registger offset randomly (default). PM - Use power management commands (default). POLL - Run in polling mode. These general-options are optional: READONLY - Read only mode (forces COMPARE=NO). SEQ=sequence - testing sequence, see ATACT.HTM. SLOW=ALL - Slow data transfer on all commands. SLOW=NONE - No slow data transfer (default). SLOW=RAND - Randomly do slow data transfer. SM=ALL - Set Multiple uses all values. SM=DEFAULT - Set Multiple uses only drive's default. SM=NONE - Disable R/W Multiple commands. SM=NORMAL - Set Multiple uses powers of 2 (default). STOP - Stop on first error of any type. STOPKB - Stop/pause on error of any type. STOP=DC - Stop on first data compare error. STOP=TO - Stop on first timeout error. STOP=UC - Stop on first uncorrectable error. STOP=OE - Stop on first other error. SYSMEM=xxxx - PC Card System/Attribute memory segment. TIME=n - Number of minutes to run. WRITEREAD - Use write and read commands (default). NONSTD=x options are: A - Set Device register bits 7 and 5 to 1. B - Execute READ BUFFER without preceeding WRITE BUFFER. C - Force SC=1 on Identify and R/W Buffer commands. D - Delay before and after stopping DMA controller. I - Ignore incorrect PUIS data in IDENTIFY word 2. M - Do not use complex DMA PRD lists. N - Do not check device 1 status after SRST. P - No polling of Alt Status during DMA commands. R - No random EXEC DEV DIAG or Soft Reset. S - Do not check signature after Soft Reset and Exec Dev Diag. Z - Do not issue commands if a device is sleeping. ATACT Ended -- Tue Jan 01 01:21:11 1980 ############################################################ ############################################################ ATACT Started -- Tue Jan 01 01:21:32 1980 ATACT -- ATA Command Test -- Version 5A0b -- using ATADRVR Version 17A. Copyright 1997-2014 by Hale Landis. All rights reserved. Technical Support: http://www.ata-atapi.com/techsupp.html This copy purchased by: FULL FREE VERSION (2019,FullFreeVersion). Customer id and number: c_free 9998. No ATAERROR environment variable found. Command line: A:\ATACT.EXE p0 WARNING: This is not a PCI system ! Options in effect... Log file name is '.\ATACT.LOG'. Testing primary device 0. CACHE, Set Features will be used to turn R/W caching on/off. COMPARE=FULL, Full data compare. FUA, Read/Write DMA/Multiple FUA commands will be used. IDP=NORMAL, Init Device Param will use 1-16 heads and 1-63 sectors. INTerrupt, IRQ (not shared) will be determined during controller setup. NODMA, Read/Write DMA commands will not be used. NOLLT, Error messages will not include low level trace. NOSTOP, An error will not stop the program. PIO=WORD, PIO data transfer will use 16-bit instructions. PM, Power management commands will be used. SEQ=n, Test sequence. SLOW=NONE, No slow data transfer on PIO Data In/Out commands. SM=NORMAL, Set Multiple will use powers of 2. TIME=60, Run time will be 1 hours 0 minutes. WRITEREAD, Write and read commands will be used. Run ID (Time Field in sector data) - Device 0: 12CEFF6CH, Device 1: 12CEFF6DH. The I/O buffer is 262144 bytes or 512 sectors of 512 bytes each. Defaulting to legacy mode - primary channel. Setting up ATA/ATAPI driver ... Using Primary I/O base addresses 01F0H:03F6H. ... done. INTerrupt mode will be set up and enabled after device set up is done. Checking ATA controller configuration ... Device Primary 0 type: ATA device. Device (not tested) type: ATAPI device. ... done. Checking device Primary 0 configuration ... Device Primary 0 is an ATA device. Executing an ID command... ...OK. This is a CFA device. Device Model: 'SunDisk SDCFB-10 ' Device Serial: ' MT302311102' Firmware Ver: 'vcb 1.34' LBA28 Total: 20480 5000H (LBA2 = ID words 60:61) LBA28 supported from LBA 0 0H to 20479 4FFFH. LBA28 sector counts are 1 to 256. LBA48 is not supported and not enabled. LBA48 Total: 0.0 0.0H (LBA3 = ID words 100:103) * LBA48 is not supported or LBA48 ID data is invalid. CHS Default: 320.2.32 140.2.20H (ID words 1, 3 and 6) CHS Default Total: 20480 5000H (LBA1 = ID words 1*3*6) CHS default supported from LBA 0 0H to 20479 4FFFH. CHS sector counts are 1 to 256. LBA28/LBA48/CHS adjusted by IDP/MINLBA/MAXSIZE/MAXTL options... LBA28 will be used in LBA range 0-20479. LBA28 sector counts will be 1 to 204. LBA48 will not be used. CHS will be used in LBA range 0-20479. CHS sector counts will be 1 to 204. Max Multiple: 1 MW-DMA support: 00, modes MW-DMA active: 00, mode U-DMA support: 00, modes U-DMA active: 00, mode ! Device may contain user data - restart ATACT using the OKTOWRITE option ! ATACT Ended -- Tue Jan 01 01:21:40 1980 ############################################################ ############################################################ ATACT Started -- Tue Jan 01 01:22:18 1980 ATACT -- ATA Command Test -- Version 5A0b -- using ATADRVR Version 17A. Copyright 1997-2014 by Hale Landis. All rights reserved. Technical Support: http://www.ata-atapi.com/techsupp.html This copy purchased by: FULL FREE VERSION (2019,FullFreeVersion). Customer id and number: c_free 9998. No ATAERROR environment variable found. Command line: A:\ATACT.EXE p0 WARNING: This is not a PCI system ! Options in effect... Log file name is '.\ATACT.LOG'. Testing primary device 0. CACHE, Set Features will be used to turn R/W caching on/off. COMPARE=FULL, Full data compare. FUA, Read/Write DMA/Multiple FUA commands will be used. IDP=NORMAL, Init Device Param will use 1-16 heads and 1-63 sectors. INTerrupt, IRQ (not shared) will be determined during controller setup. NODMA, Read/Write DMA commands will not be used. NOLLT, Error messages will not include low level trace. NOSTOP, An error will not stop the program. PIO=WORD, PIO data transfer will use 16-bit instructions. PM, Power management commands will be used. SEQ=n, Test sequence. SLOW=NONE, No slow data transfer on PIO Data In/Out commands. SM=NORMAL, Set Multiple will use powers of 2. TIME=60, Run time will be 1 hours 0 minutes. WRITEREAD, Write and read commands will be used. Run ID (Time Field in sector data) - Device 0: 12CEFF9AH, Device 1: 12CEFF9BH. The I/O buffer is 262144 bytes or 512 sectors of 512 bytes each. Defaulting to legacy mode - primary channel. Setting up ATA/ATAPI driver ... Using Primary I/O base addresses 01F0H:03F6H. ... done. INTerrupt mode will be set up and enabled after device set up is done. Checking ATA controller configuration ... Device Primary 0 type: ATA device. Device (not tested) type: ATAPI device. ... done. Checking device Primary 0 configuration ... Device Primary 0 is an ATA device. Executing an ID command... ...OK. This is a CFA device. Device Model: 'SunDisk SDCFB-10 ' Device Serial: ' MT302311102' Firmware Ver: 'vcb 1.34' LBA28 Total: 20480 5000H (LBA2 = ID words 60:61) LBA28 supported from LBA 0 0H to 20479 4FFFH. LBA28 sector counts are 1 to 256. LBA48 is not supported and not enabled. LBA48 Total: 0.0 0.0H (LBA3 = ID words 100:103) * LBA48 is not supported or LBA48 ID data is invalid. CHS Default: 320.2.32 140.2.20H (ID words 1, 3 and 6) CHS Default Total: 20480 5000H (LBA1 = ID words 1*3*6) CHS default supported from LBA 0 0H to 20479 4FFFH. CHS sector counts are 1 to 256. LBA28/LBA48/CHS adjusted by IDP/MINLBA/MAXSIZE/MAXTL options... LBA28 will be used in LBA range 0-20479. LBA28 sector counts will be 1 to 204. LBA48 will not be used. CHS will be used in LBA range 0-20479. CHS sector counts will be 1 to 204. Max Multiple: 1 MW-DMA support: 00, modes MW-DMA active: 00, mode U-DMA support: 00, modes U-DMA active: 00, mode ! Device may contain user data - restart ATACT using the OKTOWRITE option ! ATACT Ended -- Tue Jan 01 01:22:25 1980 ############################################################